How To Install Vmware Esxi On Hp Proliant Server

How To Install Vmware Esxi On Hp Proliant Server

Summary When I try to install ESXi 5.5U3 on a DL360 G6, it fails because no storage is seen. Php Serial Port Communication Linux Download. Details Hardware Server: HP Proliant DL360 G6 CPUs: 1 CPU, Intel Xeon E5506 @ 2.13GHz RAM: 48GB RAM Storage Adapter: P410i Storage: 2x 1TB HP SATA drives Storage config: RAID '10' on two drives, single 1TB 'Logical Volume' Install Process ESXi compatibility for DL360 G6: ESXi source: HPE custom ESXi 5.5 U3 from I'm booting using the ILO virtual media on an HTTP-provided ISO. This process works fine and I've had no issues with it on my local LAN. Here are some details about that generic boot process using the ILO CLI: hpiLO->power power: server power is currently: Off hpiLO->cd /map1/oemhp_vm1/cddr1 hpiLO->set oemhp_image=hpiLO->set oemhp_boot=connect hpiLO->power on After answering the usual VMware prompts, I eventually arrive at this screen and can go no farther: I've tried wiping the RAID logical volume using DBAN, just in case any prior data on there was confusing ESXi, but that changed nothing. This also shows that the storage hardware works since I was able to see the storage using DBAN just fine.

The closest related question I found so far that would be similar to this was this question:. In that case, the admin wanted a JBOD disk pass-through, which isn't possible on the HP Proliant internal storage P410i controllers. Normally I'd try loading a special HPE storage driver, but those are supposedly included on the HPE custom images. Anyone else running ESXi 5.5U3 on a DL360 G6 see this problem and get past it? Are there logs available somehow to show what's failing on the storage detection? Thanks in advance for any help! The non-HP VMware image worked great.

What the heck? I wasn't expecting that. I grabbed ESXi 5.5.0U3 from (MD5: 279685120bdb867172dc1e0c7e93514e) and the storage configuration screen showed just what I'd expect: I'm not sure what value HP is adding to those VMware images, but for Future Me or anyone else, it's worth trying the non-HP images if things don't seem to work with the HP images.

UPDATE: The HP 5.5 U2 image also works. Even though 5.5 U3 is on the compatibility list for a DL360 G6, it would appear that this release doesn't actually work properly. The 5. Cara Hack Twitter Orang Lain Lewat Hp Laptop. 5 U2 image name that works is VMware-ESXi-5.5.0-Update2-2403361-HP-550.9.2.40.2-Sep2015 (MD5: 4733f9d0d167).

↓ • Sam Lee you didn't have to add a custom ESXi firewall rule for tcp ports 2, as per the HP SUM User Guide? [excerpt below] 1. Create an httpHPSUM firewall rule that enables outgoing connection via port 63001. Create the file httpSUM.xml in the /etc/vmware/firewall directory. Type the following into the file: /etc/vmware/firewall # cat httpHPSUM.xml httpHPSUM outbound tcp dst 63001 true false 3. Refresh by using the command, esxcli network firewall refresh. Repeat the steps for port 63002.

Aplikasi Whatsap Untuk Hp Java 2018 there. Confirming on Step 4 will install the VMWare ESXi Server on your HP system. This will take some minutes to complete. After the installation the server will be rebooted.